Technical data
Rated supply voltage 100 – 277 V
AC voltage range 90 – 305 V
DC voltage range 176 – 288 V
Rated current (at 230 V, 50 Hz, full load) 0.32 A
Mains frequency 0 / 50 / 60 Hz
Efficiency (at 230 V, 50 Hz, full load) > 85 %
λ (at 230 V, 50 Hz, full load) 0.95
Output voltage tolerance 12 V -0 / +10 %
Output voltage tolerance 24 V -0 / +5 %
Output power (ta ≤ 50 °C) 60 W
Output power (ta > 50 °C) 42 W
Output power range 4.8 – 60 W
Turn on time (output) ≤ 0.5 s
Turn off time (output) ≤ 1 s
Hold on time at power failure (output) 10 ms
Mains surge capability (between L - N) 1 kV
Mains surge capability (between L/N - PE) 1 kV
Surge voltage at output side (against PE) < 500 V
Ambient temperature ta -25 ... +60 °C
Ambient temperature ta (at life-time 50,000 h) (1) -25 ... +45 °C
Storage temperature ts -40 ... +85 °C
Dimensions L x W x H 250 x 40 x 21 mm
Hole spacing D 223 mm